AEDOBP344 Accessible Parking ← All Standards ⬇ IRR PDF

BP344 · Appendix A.6

PWD Accessible Parking Requirements
BP344 Philippines (IRR 2024)

Required number of accessible slots, minimum dimensions (4000mm × 5000mm), ISA signage standards, and location requirements for PWD parking under Batas Pambansa Blg. 344.

BP344 · Appendix A.6

Parking Provisions

A.6.1Accessible stall: minimum 4000 mm wide × 5000 mm long. The extra width vs standard slot ensures adjacent pathway accommodates wheelchair passage.
A.6.2Walkway min 1200 mm between front ends of parked cars. Stall surface: firm, level, no aeration slabs. Dropped sidewalk or curb ramp to parking level where walkways are raised.
A.6.3PWD access only: passenger with disability must be inside vehicle. Access parking placard with control number and PWD ID conspicuously hung on rear-view mirror.
A.6.4Pole-mounted ISA sign: 600 mm × 600 mm, min clear height 2200 mm from parking floor. Pavement ISA symbol: 1000–1500 mm square centered in stall, white figure on UN Blue (#5B92E5).
A.6.5Multi-story parking: accessible slots adjacent to elevators. Multiple entrances: slots dispersed nearest each accessible entrance. Never locate in ramped or sloping areas.

Key Dimensions

ACCESSIBLE PARKING SLOT — CRITICAL MEASUREMENTS
Stall Width (min)4000 mm
Stall Length5000 mm
Front Walkway1200 mm min
Pole Sign Size600 × 600 mm
Sign Clear Height2200 mm from floor
Floor ISA Symbol1000–1500 mm square
ISA ColorWhite on UN Blue #5B92E5
Total Parking SlotsRequired Accessible Slots
1 – 251
26 – 502
51 – 753
76 – 1004
101 – 1505
151 – 2006
201 – 3007
301 – 4008
401 – 5009
501 – 10002% of Total
1001 & Over20 + 1 per 100 over 1000

Reference Diagrams

Accessible Parking Perspective View — BP344
Accessible Parking · Perspective View
Plan of Accessible Parking Slot — BP344 Fig. A.6.1
Fig. A.6.1 · Plan of Parking Slot

Frequently Asked Questions

How many PWD parking slots are required for a 100-slot parking facility?
Per BP344 Table A.6.1, a facility with 76–100 total parking slots must provide 4 accessible slots.
Can the accessible parking slot be in a sloped area?
No. BP344 explicitly prohibits locating accessible parking slots in ramped or sloping areas. The surface must be firm, level, and free of aeration slabs.
What color is the ISA symbol on accessible parking floors?
The International Symbol of Access (ISA) must be painted as a white figure on a UN Blue background (#5B92E5 / Pantone 279), centered in the stall at 1000–1500mm square.