AEDOBP344 Doors & Entrances ← All Standards ⬇ IRR PDF

BP344 · Appendix C.2

Accessible Door & Entrance Requirements
BP344 Philippines (IRR 2024)

Minimum clear door width (900mm), lever hardware height, kick plate specifications, peephole heights, and maneuvering clearance requirements per the 2024 amended IRR.

BP344 · Appendix C.2

Door & Entrance Provisions

C.2.1Minimum clear opening width: 900 mm for both sliding doors (fully open) and swing doors (90° open position).
C.2.2Door hardware height: 900 mm from finished floor. Lever-type handles and latches preferred over knobs for persons with limited grip strength.
C.2.3Kick plate: 300 mm high from floor. Protects door from wheelchair footrests and provides visual contrast.
C.2.4Peepholes (where provided): dual peepholes at 900 mm (standard) and 1000 mm (for wheelchair users).
C.2.5Vertical door pull recommended on pull side. Accessible toilet cubicle doors shall swing outward.

Key Dimensions

ACCESSIBLE DOOR — CRITICAL MEASUREMENTS
Min Clear Width900 mm
Hardware Height900 mm from floor
Hardware TypeLever (not round knob)
Kick Plate Height300 mm from floor
Peephole (standard)900 mm
Peephole (wheelchair)1000 mm
Toilet Door SwingOutward

Reference Diagrams

Door with Dual Peepholes — BP344 Fig. C.2.2
Fig. C.2.2 · Dual Peepholes
Door Accessories — BP344 Fig. C.2.1
Fig. C.2.1 · Door Accessories